Features
True-RMS AC voltage and current for accurate measurements on non linear signals
Yes
Selectable filter for accurate voltage and frequency measurements on motor drives
Yes
6000 counts, 3-3/4 digits
Yes
4-1/2 digit mode for precise measurements (20,000 counts)
Yes
Measure up to 10 A, 20 A for up to 30 seconds
Yes
Built in thermometer lets you carry one less tool (TC probe included)
Yes
Frequency to 200 kHz and % duty cycle
Yes
Resistance, continuity and diode test
Yes
10,000 µF capacitance range for components and motor caps
Yes
Min/Max-Average recording with Min/Max Alert to capture variations automatically
Yes
Battery Life with Backlight off
400 hours
Accuracy
Functions
Range
Basic Accuracy
DC volts
600.0 mV, 6.000 V, 60.00 V, 600.0 V, 1000 V
0.05%
AC volts
600.0 mV, 6.000 V, 60.00 V, 600.0 V, 1000 V
0.7% (True-RMS)
DC current
600.0 µA, 6000 µA, 60.00 µA, 600.O mA, 6.000 A, 10.00 A
0.2%
AC current
600.0 µA, 6000 µA, 60.00 µA, 600.O mA, 6.000 A, 10.00 A
1.0% (True-RMS)
Temperature (excl. probe)
-200°C to 1090°C
1.0%
Temperature Probe
-40°C to 260°C
2.2°C or 2%
Resistance
600.0 Ω, 6.000 kΩ, 60.00 kΩ, 600.0 kΩ, 6.000 MΩ, 50.00 MΩ
0.2%
Capacitance
10.00 nF, 100.0 nF, 1.000 µF, 10.00 µF, 100.0 µF, 9,999 µF
1.0%
Frequency
199.99 Hz, 1.9999 kHz, 19.999 kHz, 199.99 kHz
0.005%